Home Inquiry Sitemap
 
The Only Trusted One in Submersible Pump cable  
HOME PROFILE PRODUCTS QUALITY EXPORT INQUIRY CONTACT
 
 
  PVC 3 Core Flat Cables

CABLE DESIGN: A submersible Pump cable is a specialized product to be used for submersible pumps in a deep well. The area of installation is physically restrictive, and the environment is very hostile. Jainson is designed and manufactured keeping in mind these factors to achieve the highest possible degree of reliability

 FEATURE :
Quality backed by 40 years experience in cable industry.
Excellent resistant to moisture, abrasion, grace, oil.
Longer Flex Life
Excellent mechanical & electrical properties.
Generally Conforming to : CENELEC HD 21, IEC 60227,
  BS 6500, DIN VDE 0281, IS 694.
Approved by GWSSB, GWRDC, TWAD, PHED, PSTC, ONGC,
  Railways, Mines etc.
Tested by SGS, EIL, RITES, NPC, INTERTEK.
 
APPLICATION :
For continuous use in deep well to supply power to submersible pumps down to depths of 500 mtrs.
Manufacturers and Expoters of 3 core flate cables .
JAINSON 3CORE FLAT CABLES FOR SUBMERSIBLE PUMPS (1100 VOLTS)
CONDUCTOR PVC INSULATION PVC SHEATH Conductor Resistance at 20°C (max) ohms/km Current
Rating at
40°C
Amps.
Nominal
Area in
Nos. & Dia.
of wire
  
Nominal
Thickness
Nominal
Core Dia.
Nominal
Thickness
Approx. Overall
Dimensions
Sq. mm. Nos. / mm mm mm mm Thickness
mm
Width
mm
1.50 22/0.30 0.80 3.25 1.15 6.00 12.80 12.10 14
2.50 36/0.30 0.90 3.84 1.15 6.40 14.60 7.41 18
4.00 56/0.30 1.00 4.50 1.15 7.40 16.80 4.95 26
6.00 85/0.30 1.00 5.30 1.15 7.90 18.70 3.30 31
10.00 140/0.30 1.00 6.50 1.40 9.90 23.70 1.91 42
16.00 226/0.30 1.00 8.00 1.40 11.40 28.00 1.21 57
25.00 354/0.30 1.20 10.10 2.00 14.70 35.50 0.780 72
35.00 495/0.30 1.20 11.30 2.00 16.20 39.50 0.554 90
50.00 703/0.30 1.40 13.60 2.20 18.30 45.50 0.386 115
70.00 440/0.45 1.40 15.30 2.20 20.00 51.00 0.272 143
95.00 475/0.50 1.60 18.00 2.40 23.50 60.00 0.206 165


       Note :

  • The number of wires is approximate and wire diameter is nominal; they shall be such as to satisfy the requirements of conductor resistance as per Class 5 of IEC 60228 / DIN VDE 0295 / IS 8130 / BS 6360
  • In view of continuous improvements in our design and process, specifications given here in are subject change without notice.
3 Core Flat Cables as per IS 694 : 1990 with ISI mark
CONDUCTOR PVC INSULATION PVC SHEATH Current Rating at 40°C Amps.
Nominal Area
Sq. mm
Nos. Dia Of Wire
Nos./mm
Nominal Thickness Nominal Thickness Approx Overall Dimension
mm mm Thickness
mm
Width
mm.
1.5 22/0.30 0.6 0.9 5.20 11.30 14
2.5 36/0.30 0.7 1.0 6.20 13.30 18
4.0 56/0.30 0.8 1.0 7.00 15.60 26
6.0 84/0.30 0.8 1.1 7.40 17.70 31


        Note :

  • The number of wires is approximate and wire diameter is nominal.
  • They shall be so as to satisfy the requirements of conductor resistance as per
    • Class 2 of IS 8130 : 1984 (For 1.5 & 2.5 sq. mm.) &
    • Class 5 of IS 8130 : 1984 (For 4.0 & 6.0 sq. mm.)
 
  Submersible pump cables
  +   PVC 3 Core Flat Cables
  +   PVC 4 Core Flat Cables
  +   PVC 3 Core Round Cables
  +   PVC 4 Core Round Cables
  +   Rubber 3 Core Flat Cables
  +   Rubber 4 Core Flat Cables
  +   Rubber 3 Core Round  Cables
  +   Rubber 4 Core Round Cables
  +   DRINCABLE
  +   H07RN-F CABLES
  Flexible Cables |  
  Welding Cables |
 
All Rights Reserve jainson submersible pump cables Provided by : netservicesindia