H07RN-F
For Submersible Pump Cables - 450/750 V. |
 |
|
CABLE
DESIGN :
Submersible
Pump cables is a specialized
product to be used for submersible
pumps in a deep well. The area
of installation is physically
restrictive, and the environment
is very hostile. Jainson is
designed and manufactured keeping
in mind these factors to achieve
the highest possible degree
of reliability
|
Technical
Details :
Rubber Sheathed cable CENELEC
HD 22.1.S2, DIN VDE 0282 PART
810, IEC 245, CEI 20-19 &
BS 6007, BS 6899. |
FEATURES
& PROPERTIES :
Designed for heavy duty use.
Cur, tear & abrasion resistant.
Exceptional long term performance.
Excellent resistant to oils,
chemicals, ozone & solvents.
Excellent Impact Resistant.
Excellent Weather Resistant.
Performs & Looks like Vulcanize
Rubber.
Excellent Electrical Properties.
Temperature range -40° to
+90° |
| |
| APPLICATION
: |
| For
continuous use in deep
well to supply power to
submersible pumps down
to depths of 500 mtrs. |
| |
| CONSTRUCTION
: |
Conductor
: Plain annealed
flexible copper Insulation
: EPR
Sheath/Jacket
: PCP Or Synthetic
Rubber (Oil resistant
& flame retardant)
Core Colours :
3core : Brown, Blue
& Green / Yellow
4core : Brown, Blue, Black
& Green / Yellow |
| |
|
|
 |
 |
|
 |
|
RUBBER 3CORE ROUND CABLES FOR
SUBMERSIBLE PUMPS (450/750
VOLTS) |
| CONDUCTOR
|
PVC INSULATION |
TOTAL
THICKNESS OF RUBBER SHEATH
|
Nominal
Area in
|
Nos.
& Dia.
of wire
|
Nominal
Thickness |
Mean
Overall Diameter |
| Lower
Limit |
Upper
Limit |
| Sq.
mm. |
Nos.
/ mm |
mm |
mm |
mm |
| 1.50 |
22/0.30 |
0.80 |
09.20 |
11.90 |
| 2.50 |
36/0.30 |
0.90 |
10.90 |
14.00 |
| 4.00 |
56/0.30 |
1.00 |
12.70 |
16.20 |
| 6.00 |
85/0.30 |
1.00 |
14.10 |
18.00 |
| 10.00 |
140/0.30 |
1.20 |
19.10 |
24.20 |
| 16.00 |
226/0.30 |
1.20 |
21.80 |
27.60 |
| 25.00 |
354/0.30 |
1.40 |
26.10 |
33.00 |
| 35.00 |
495/0.30 |
1.40 |
29.30 |
37.10 |
| 50.00 |
703/0.30 |
1.60 |
34.10 |
42.90 |
| 70.00 |
440/0.45 |
1.60 |
38.40 |
48.30 |
| 95.00 |
475/0.50 |
1.80 |
43.30 |
54.00 |
|
|
RUBBER 4CORE ROUND CABLES FOR SUBMERSIBLE
PUMPS (450/750
VOLTS) |
| CONDUCTOR
|
PVC
INSULATION |
TOTAL
THICKNESS OF RUBBER SHEATH |
Nominal
Area in
|
Nos.
& Dia.
of wire
|
Nominal
Thickness |
Mean
Overall Diameter |
| Lower
Limit |
Upper
Limit |
| Sq.
mm. |
Nos.
/ mm |
mm |
mm |
mm |
| 1.50 |
22/0.30 |
0.80 |
10.20 |
13.10 |
| 2.50 |
36/0.30 |
0.90 |
12.10 |
15.50 |
| 4.00 |
56/0.30 |
1.00 |
14.00 |
17.90 |
| 6.00 |
85/0.30 |
1.00 |
15.70 |
20.00 |
| 10.00 |
140/0.30 |
1.20 |
20.90 |
26.50 |
| 16.00 |
226/0.30 |
1.20 |
23.80 |
30.10 |
| 25.00 |
354/0.30 |
1.40 |
28.90 |
36.60 |
| 35.00 |
495/0.30 |
1.40 |
32.50 |
41.10 |
| 50.00 |
703/0.30 |
1.60 |
37.70 |
47.50 |
| 70.00 |
440/0.45 |
1.60 |
42.70 |
54.00 |
| 95.00 |
475/0.50 |
1.80 |
48.40 |
61.00 |
|
| |
Note
:
- The number of wires is approximate and
wire diameter is nominal; they shall be
such as to satisfy the requirements of
conductor resistance as per Class 5 of
IEC 60228 / DIN VDE 0295 / IS 8130 / BS
6360
- In view of continuous improvements in
our design and process, specifications
given here in are subject change without
notice.
|
|
|
|